Logic
Definition
Block pulses during
IBL OPEN
opening
Block pulses during
|IBL TCA
TCA
Block pulses during
IBL CLOSE
closing
Open in other
OPEN IN OTHER
direction
DIRECT.
Configuration of
safety input SAFE 1.
SAFE 1
72
Configuration of
safety input SAFE 2.
SAFE 2
74
Configuration of
safety input SAFE 3.
SAFE 3
77
Configuration of
command input IC 1.
IC 1
61
Configuration of
command input IC 2.
IC 2
62
Configuration of
command input IC 3.
IC 3
64
Configuration of
command input IC 4.
IC 4
65
INSTALLATION MANUAL
Cross
out
Default
setting
used
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
0
 
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during TCA pause.
0
 
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during TCA pause.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during closing.
0
 
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during closing.
0
Standard operating mode
0
 
1
Opens in other direction to standard operating mode
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
0
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
 
8
Input configured as Bar 8k2.
Input configured as Bar OP, safety edge with inversion active only while opening. If while closing, the
9
movement stops.
6
Input configured as Bar OP TEST, safety edge tested with inversion active only while opening. If while
10
closing, the movement stops.
Input configured as Bar OP 8k2, safety edge with inversion active only while opening. If while closing,
11
the movement stops.
Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the
12
movement stops.
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while
13
opening, the movement stops.
Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening,
14
the movement stops.
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
2
 
7
Input configured as Bar, tested safety edge.
8
NOT AVAILABLE
Input configured as Bar OP, safety edge with inversion active only while opening. If while closing, the
9
movement stops.
Input configured as Bar OP TEST, safety edge tested with inversion active only while opening. If while
10
closing, the movement stops.
11
NOT AVAILABLE
Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the
12
movement stops.
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while
13
opening, the movement stops.
0
Input configured as Start E.
0
1
Input configured as Start I.
2
Input configured as Open.
4
3
Input configured as Close.
 
4
Input configured as Ped.
2
5
Input configured as Timer.
3
6
Input configured as Timer Pedestrian.
Optional extras