INTRODUCTION
Always consult your local Building Department regarding regulations,
codes or ordinances which apply to the installation of a vented wall
furnace.
INSTRUCTIONS TO INSTALLER
1. Installer must leave instruction manual with owner after
installation.
2. Installer must have owner fill out and mail warranty card supplied
with furnace.
3. Installer should show owner how to start and operate furnace.
Any change to this furnace or its control can be dangerous.
This is a heating appliance and any panel, door or guard
removed for servicing an appliance must be replaced prior
to operating the appliance.
To Conserve Gas: Turn off pilot when heater is not in use.
GENERAL INFORMATION
This series is design certified in accordance with American National
Standard / CSA Standard Z21.86 and CSA 2.32 by the Canadian
Standards Association, as a Fan Type Vented Wall Furnace and
must be installed according to these instructions.
Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not
shown on the rating plate is the responsibility of the person
and company making the change.
IMPORTANT
All correspondence should refer to complete Model No., Serial No.
and type of gas.
NOTICE: During initial firing of this unit, its paint will bake out and
smoke will occur. To prevent triggering of smoke alarms, ventilate
the room in which the unit is installed.
INSTALLATION ON RUGS AND TILE
If this appliance is installed directly on carpeting, tile or other
combustible material other than wood flooring the appliance shall
be installed on a metal or wood panel extending the full width and
depth of the appliance.
The base referred to above does not mean the fire-proof base as
used on wood stoves. The protection is for rugs that are extremely
thick and light colored tile.
Page 2
INTRODUCTION
WARNING
WELL HEAD GAS INSTALLATIONS
Some natural gas utilities use "well head" gas. This may affect
the Btu output of the unit and promote sooting. Units shall not be
converted to use well head gas.
INSTALLATION IN RESIDENTIAL GARAGES
Gas utilization equipment in residential garages shall be installed
so that all burners and burner ignition devices are located not less
than 18" (457mm) above the floor.
Such equipment shall be located, or protected, so it is not subject
to physical damage by a moving vehicle.
SPECIFICATIONS
Model
Input BTU/HR (KW/H)
Height
72 1/2" (84.1mm)
Width
14 1/8" (35.9mm)
Depth
10 3/8" (26.4mm)
Gas Inlet Pipe
1/2" (12.7mm)
Vent Collar Type B Oval
CFM
ACCESSORIES
Register, side outlet, fixed register
Side outlet, 10" (254mm)
maximum extension, fixed register
Rear outlet, 10" (254mm)
maximum extension, adjustable register
Vent enclosure, 24" (609mm)
[for rooms up to 96 1/2" 2451mm) in height]
Vent enclosure, 34" (86cm)
[for rooms up to 106 1/2" (2705mm) in height]
Vent enclosure, 46" (1168mm)
[for rooms up to 118 1/2" (3009mm) in height]
Oval-to-Round flue adapter kit 4" (102mm)
CONVERSION KITS
Model Number
Description
DV1351
Propane to Natural
DV1349
Natural to Propane
DV1347
Propane to Natural
DV1345
Natural to Propane
FAW-40SPP
FAW-40IP
40,000 (11.7)
40,000 (11.7)
72 1/2" (184.1mm)
14 1/8" (35.9mm)
10 3/8" (26.4mm)
1/2" (12.7mm)
4" (101mm)
4" (101mm)
275
275
SOR-1
SOK-1
ROK-1
FVE-24DB
FVE-34DB
FVE-46DB
DV648DBF
Used On
FAW40IPXLP-1
FAW40IPXNAT-1
FAW40SPPXLP-1
FAW40SPPXNAT-1
37134-6-0520