remaining sanitising solution from the bottom of the containers.
Do not perform further rinsing.
8 ROUTINE MAINTENANCE
1 Every day: inspect the dispenser and check for leaks of
product from the gaskets. If you notice leaks, first make sure
that the components of the dispenser are properly installed,
then check that the gaskets do not require lubrication and
finally that they are not worn or damaged. If they are, replace
them with original spare parts from the manufacturer.
2 Every month: check that the hexagonal joint gasket is not
worn. If it is, replace the joint itself with an original spare part
from the manufacturer (see figure 20).
figure 20
3 Every month: remove the dust from the condenser filter on
the back of the machine (see figure 21).
figure 21
ATTENTION
Beware of the condenser fins as they are sharp.
4 In case of noise it needs to unplug the cooler and call for
service.
5 In case of failure unplug the machine, because unexpected
start again would be possible.
6 It needs to fix everything back in the initial position after any
repairmen, like screws and covers.
8. 1 MAINTENANCE (TO BE CARRIED OUT BY
QUALIFIED SERVICE PERSONNEL ONLY)
IMPORTANT
In order to prevent damage to the dispenser, the plastic
parts must only be lubricated with the grease supplied by
the manufacturer or with another type of grease compati-
ble with plastic parts.
1 Annually: Remove all the panels and clean the inside of
the machine including the base and the inside of the panels.
Never remove the anti-condensation material wrapped around
the evaporator outlet tube (the copper tube located to the right
of the geared motor). If said material is missing or lost, replace
with original spare parts from the manufacturer.
2 Remove any traces of product from the inside of the
evaporator by removing the tray as shown (see figure 22).
22
figure 22