Operating Instructions
MaxLite CCT Selectable WallMax™ Open Face
®
Note: Add a bead of exterior grade silicone sealant around the perimeter of the wall pack on the wall to inhibit any moisture
Installation & Operation - Conduit Mounting:
from attachment bolts.
1. Unscrew the screws on the right side of the fixture
using a suitable Phillips screw driver. Separate the
male and female connectors connecting the driver
DC wires to the LEDs, then remove the reflector
from the back plate.
Reflector
Male
Connector
3. Run the main power supply wires through the
knockout hole removed in step 2. Connect the
main power to the driver according to the wiring
diagram.
© Copyright 2021. MaxLite, Inc. All Rights Reserved.
12 York Ave, West Caldwell, NJ 07006 Tel: 800-555-5629 Fax: 973-244-7333 Email: info@maxlite.com
Female
Connector
2. Remove the knockout plug from the side of the fixture that the
power will run through. Drill three (3) holes in locations indicated
by E/F/G. Fasten the back plate to the wall with three (3) anchor
bolts.
E
4. Place the reflector back onto the back plate using the hinge
mechanism. Next, connect the male and female connectors
together. Finally, use a suitable screwdriver to connect the
reflector to the back plate to seal the fixture.
Reflector
Male
Connector
WPOP Series
F
G
Main Power
Back Plate
Female
Connector
Page: 3