 The microwave oven must be installed more than 850 mm above floor.
 Choose the setup location in such a way that children cannot reach any hot surfaces on
the device.
 The device is not intended to be installed in a wall or a built-in cupboard.
 Do not set up the device in a hot, wet or extremely damp environment or near
flammable material.
 The device requires an adequate flow of air in order to operate correctly. Leave a
clearance of 20 cm above the oven, 10 cm around the back and 5 cm on both sides.
 Do not cover up any openings on the device and do not block these off.
 Do not remove the device's adjustable feet.
 The electrical socket must be easily accessible so that the power lead can be
disconnected easily, in the case of an emergency.
 The installation and assembly of this device in non-stationary setup locations (e.g. on
ships) must be carried out by specialist companies / electricians, provided they
guarantee the prerequisites for the safe use of this device.
13.5.2

Avoiding radio interference

The device can cause the occurrence of interference in radios, televisions or similar
devices. Such faults can be rectified or reduced as a result of employing the following
measures:
 Clean the door and the sealing surfaces of the device.
 Set the radio, the television, etc as far as possible away from the device.
 Connect the device to a different electrical outlet, so that various power circuits are used
for the device and the receiver with the interference.
 Use a properly installed antenna for the receiver, to ensure good reception.

13.6 Electrical connection

In order to ensure the safe and trouble-free operation of the device, the following
instructions must be observed for the electrical connection:
 Before connecting the device, compare the connection data (voltage and frequency) on
the rating plate with those of your electrical network. This data must agree in order that
no damages occur in the device. If in doubt, ask your qualified electrician.
 The electrical outlet must be protected by a 16A safety cut-out switch, separately from
other electricity consumers.
 The connection between the device and the electrical network may employ a 3 meter
long (max.) extension cable with a cross-section of 1.5 mm². The use of multiple plugs
or gangs is prohibited because of the danger of fire that is involved with this.
 Make sure that the power cable is undamaged and has not been installed under the
oven or over hot or sharp surfaces.