Do not use the device or store it in damp places such as a bathroom.
Do not use the device if the USB cable is damaged.
Keep the USB cable away from hot surfaces.
Read and note the "Important information about electromagnetic compatibility (EMC)"
displayed in the Technical Data section.
This device must not be left unsupervised if used by, or close to, children or the infirm.
Check that the components have been fixed correctly.
Make sure that the spray cap has been installed correctly prior to use.
Check that the air filter has been fixed correctly.
Check that the air filter is clean. If the air filter has changed colour or been in regular use
for over 60 days, replace it with a brand new air filter.
Do not spill any liquid or any of the drug on the compressor.
Do not tilt the nebulisation kit at an angle of more than 45° in any direction and do not
shake it while it is running.
Do not use or store the device if there are folds in the air tube.
Use only original nebulisation components, air tube, air filter and air filter cover.
Do not add more than 10ml of the drug to the drug reservoir.
Do not carry or remove the nebulisation kit when the drug reservoir contains a drug.
Do not leave the device unsupervised in the presence of young children or individuals
who cannot give their consent.
Do not subject the device or its components to violent shocks such as, for example, drop-
ping the device onto the floor.
Do not twist the spray cap or push a pin or pointed object through the cannula of the
drug reservoir.
Do not insert your fingers or any objects in the compressor.
Do not dismantle or attempt to repair the compressor or USB cable.
Do not leave the device or its components in places where the temperature is beyond the
range of those indicated in the technical data of these instructions for use.
Do not leave the device or its components in places where they will be exposed to extreme
temperatures or changes in humidity, such as in a vehicle at the height of summer or in
places where they will be exposed to direct sunlight.
Do not block the air filter cover.
When you disinfect components by boiling them, make sure the container is not dry-heated.
Never use the device when you are going to sleep or are drowsy.
Do not obstruct the slot between the cartridge and the air inlet of the inhalation system.
Do not use the microwave oven, dishwasher drier or hairdryer to dry the device or its
components.
Authorised for human use only.
Continuous use of the device may reduce its lifespan. Do not use this device for more than
15 minutes at a time and wait for at least 40 minutes before using it again.
The main unit may get hot when the device is in use.
Do not touch the main unit except when necessary, for example to switch the device
off during nebulisation.
To prevent any of the drug remaining on your face, make sure you cleanse your face
after taking off the mask.
Risk of electric shock
Always remove the batteries or always disconnect the USB cable after use and before cleaning.
Any changes or modifications that have not been approved by LANAFORM will cancel
the user's warranty.
EN
GENERAL SAFETY PRECAUTIONS
Examine the device and the components before each use and make sure that no anomalies
are found. Check the following points in particular:
·
The spray cap, cannula, child's/adult's mask and the air tube must not be damaged.
·
The cannula must not be obstructed.
·
The compressor must run normally.
The compressor pump emits sounds and vibrations when this device is in use. Compressed
air emission from the nebulisation kit also generates noise. This noise is normal and is not
the sign of a malfunction.
Use the device only for the intended purposes. Do not use it for any other purpose.
Do not use the device at temperatures above +40°C and below 5°C.
Check that the air tube is correctly attached to the compressor and nebulisation kit and that
it does not become loose. When you insert the air tube plug into the air tube connectors,
screw it loosely to prevent the air tube becoming disconnected when in use.
Remove the batteries if the device is not used for more than 3 months.
Read and take note of the "How to dispose of this product" procedure in the Technical
Data section when you discard the device and the old optional accessories or components.
Look after these instructions carefully so that you can refer to them at a later date.