English
Connecting the manifold
a) with DIGIMON-SE
Connect blue hose (1)
Connect red hose (2)
Connect yellow hose (3)
Close both valves (5+6)
b) with DIGIMON4
Connect blue hose (1)
Connect red hose (2)
Connect yellow hose 3/8" (3)
Connect yellow hose 1/4" (4)
Close both valves (5+6)
Evacuating the system
Switch on the manifold
Press the
Connect the hoses
Switch on vacuum pump
Open all valves
Check vacuum display
When the ultimate vacuum is achieved, close all valves.
Press the
Evacuation time varies depending on the size of the system. A small to
medium-sized system requires a minimum evacuation time of 20 minutes.
12
VAC
button
LP/HP
button to exit vacuum mode.
Instruction Manual DIGIMON-SE / DIGIMON4
to suction pressure side of system
to high pressure side of system
to vacuum pump
to suction pressure side of system
to high pressure side of system
to vacuum pump
to refrigerant cylinder