Electrical Connection

I WARNING
ELECTRICAL SHOCK HAZARD.
I WARNING
DISCONNECT POWER BEFORE SERVICING.
REPLACE ALL PARTS AND PANELS BEFORE OPERATING.
FAILURE TO DO SO CAN RESULT IN DEATH OR
ELECTRICAL SHOCK.
1
Disconnect power.
2
Remove terminal box cover.
3
Remove the knockout in the terminal box cover and install
a UL listed or CSA approved
A
A. Knockout
B. Junction box cover
4
Run home power supply cable through strain relief, into
terminal box.
A
C
D
E
A. Home power supply cable
B. UL listed or CSA approved strain
relief
C. Black wires
5
Use UL listed wire connectors and connect black wires
(C) together.
6
Use UL listed wire connectors and connect white wires (E)
together.
I WARNING
ELECTRICAL SHOCK HAZARD.
I WARNING
ELECTRICALLY GROUND BLOWER.
CONNECT GROUND WIRE TO GREEN AND YELLOW
GROUND WIRE IN TERMINAL BOX. FAILURE TO DO SO CAN
RESULT IN DEATH OR ELECTRICAL SHOCK.
7
Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (F) in terminal box
using UL listed wire connectors.
8
" strain relief.
1
2
B
B
F
D. UL listed wire connectors
E. White wires
F. Green (or bare) and yellow-green
ground wires
8
Tighten strain relief screw.
9
Install terminal box cover.
10 Check that all light bulbs are secure in their sockets.
11 Reconnect power.
Install duct covers
• When using both upper and lower vent covers, push lower
cover down onto hood and lift upper cover to ceiling and
install with two mounting screws.
NOTE: For vented installations, the upper vent cover may be
reversed to hide slots.
A
B
A. Upper vent cover
B. Lower vent cover
• Secure the bottom of the duct with 2 - 4 x 8 mm screws.

Complete Installation

• For non-vented (recirculating) installations only, install
charcoal filters over metal grease filter.
See the "Mainteinance" section.
• Install metal filters. See the "Mainteinance" section.
If range hood does not operate:
Check that the circuit breaker is not tripped or the house
fuse blown.
• Disconnect power supply. Check that wiring is correct.
To get the most efficient use from your new range hood,
read the "Mainteinance" section.
Keep your Installation Instructions and Use and Care Guide
close to range hood for easy reference.
C
D
C
C. 4 x 8 mm screws
D. Bracket

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Etb436s3

Table des Matières