Télécharger Imprimer la page

Anest Iwata LPH-80-044G Manuel D'utilisation Et D'entretien page 2

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
EN
LPH-80 (LVLP
Before use, adjustment or maintenance, it is important to read
this instruction manual very carefully. This manual must be
stored in a safe place for any future reference.
This ANEST IWATA spray guns kit complies to ATEX
regulations ATEX 2014/34/EU.
Protection level: II 2 G X Suitable for using Zones 1 and 2.
X marking: Any static electricity discharged from the spray gun is to be diverted
to the ground via the conductive air hose as stipulated.
ALWAYS observe WARNINGS and CAUTIONS in this
instruction manual.
Symbol
WARNING
Hazard level
WARNING
CAUTION
IMPORTANT
1. TECHNICAL SPECIFICATIONS
Max. working air pressure:
Weight g (lbs): (without cup)
Noise level (LAeqT)*:
Air Connection:
Fluid Connection:
Max. Temperature range:
* Measuring point: 1m backwards from gun, 1.6 m height.
1.1 TECHNICAL DATA
Models
LPH-80-044G
0.4
LPH-80-064G
0.6
LPH-80-084G
0.8
E4
LPH-80-104G
1.0
LPH-80-124G
1.2
2. SAFETY WARNING
FIRE AND EXPLOSION
Never use the following HALOGENATED HYDROCARBON SOLVENTS:
which can cause cracks or dissolution of gun body (aluminium) due to chemical
reaction. UNSUITABLE SOLVENTS: methyl chloride, dichloromethane, 1.2-dichlo-
roethane, carbon tetrachloride, trichloroethylene, 1.1.1-trichloroethane
Sparks and open flames are strictly prohibited. Paints can be highly flam-
mable and can cause fire. Do not expose to open flames, electrical goods,
cigarettes etc.
Securely ground spray gun using conductive air hose. (<1MΩ) Always
ensure that the spray gun is earthed correctly.
PROTECTION OF HUMAN BODY
Use in a well-ventilated site, using a spray booth. Poor ventilation can
cause organic solvent poisoning and fire.
Always wear protective gear (safety glasses, mask, gloves) to avoid
inflammation of eyes and skin. In case of any physical discomfort, immedia-
tely seek medical advice.
2
) Spray Gun for
Consequence
Death or serious injury
POTENTIALLY
HAZARDOUS
Minor to moderate injury
SITUATION
Property damage
6.8 bar (98 PSI)
205 (0.45)
60.3 dB(A)
G1/4"
G1/8"
Atmosphere 5 ~ 40 °C / Air-Fluid 5 ~ 43 °C
10
30
1.0
45
60
60
75
Wear earplugs if necessary. Noise level can exceed 85 dB(A), depending on
operating conditions and painting site.
Pulling the trigger many times during operation, may cause carpal
tunnel syndrome. Always rest, in case of tiredness.
IMPROPER USE
Never point gun towards people or animals.
Never exceed maximum working pressure or maximum operating
Temperature
Always release air and fluid pressure before cleaning, disassembling
or servicing. Otherwise, remaining pressure can cause bodily injury due to
improper operation or scattering of cleaning liquid.
Tip of fluid needle set has a sharp point.
Do not touch the tip during maintenance to avoid accidents.
Never use this gun to spray foods or chemicals. Otherwise, foreign
substance, could cause corrosion of fluid passages which could adversely
affect health.
Never alter this spray gun, to avoid insufficient performance and damage.
If something goes wrong, immediately stop operation and find the
cause. Do not use again, until you have solved the problem.
Do not enter working areas, where robots, reciprocators, etc. are used,
until they have been turned off. Otherwise, they could cause injury.
3. HOW TO CONNECT
CAUTION
Use clean air filtered through air dryer and air filter.
When using this gun for the first time after purchase, adjust fluid nee-
dle packing set, spray cleaner to clean fluid passages and remove rust
preventive oil.
Firmly fix cup to spray gun, to avoid that disconnection of it, can cause
bodily injury.
55
1. Firmly connect an air hose to air nipple 1/4" (8-2).
80
2. Firmly connect a suitable cup to fluid nipple G1/8".
100
3. Flush fluid passages with a compatible cleaner.
4. Pour paint into container, test spray, adjust fluid output and pattern width.
130
140
4. HOW TO OPERATE
Suggested atomizing air pressure is 0.5~1.0 bar (7~14 PSI). In this way
the gun will atomize within 0.7 bar (10 PSI) inside air cap. NOTE: To have a
correct air volume to atomize to 0.7 bar (10 PSI), using an air hose of 12 m
long, the inner hose diameter must be minimum 8mm.
Recommended paint viscosity differs according to paint property and painting
conditions. 12 to 20 sec. / Ford cup#4 is recommended.
Set the spray distance from the gun to the work piece, as near as possible
within the range of 50-150 mm (2 - 5.9 in).
The gun should be held so that it is perpendicular to the surface of the work-
piece at all times. Then, the gun should move in a straight and horizontal
line. Arcing the gun causes uneven painting.
SPOT REPAIR
Atomizing air pressure
Air regulator outlet pressure

Publicité

loading

Ce manuel est également adapté pour:

Lph-80-064gLph-80-084gLph-80-104gLph-80-124g