DANGER
product.
- To avoid possible electrical shock, special
care should be taken since water is/ may be employed in the
use of this product. For each of the following situations, do not
attempt repairs yourself; return the product to an authorized
service facility for service if it is still under warranty or discard
the product. Do not operate the appliance if it has a damaged
electrical cord or plug, or if it is malfunctioning or if it is dropped
or damaged in any manner. The power supply cord for this unit is
detachable and can be replaced if damaged. Replace supply cord
only with original Exo Terra
2. To avoid injury, do not contact moving or hot parts.
CAUTION -
3.
Always unplug or disconnect the appliance from
the outlet before putting on or taking off parts and while the
equipment is being installed, maintained or handled. Never yank
the cord to pull the plug from outlet. Grasp the plug and pull to
disconnect. Always unplug an appliance from an outlet when not
in use. Never lift this product by the cord.
4. This appliance is not intended for use by persons (including
children) with reduced physical sensory or mental capabilities,
or lack of experience or knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.
5. The use of attachments not recommended or sold by the
appliance manufacturer may cause an unsafe condition.
6. Do not install or store the appliance where it will be exposed to
temperatures below freezing. Do not expose the unit to direct sunlight.
7. Ensure that the appliance is placed on a flat, even surface.
Monitor the product regularly. Do not leave the product
4
unattended for extended periods.
8. If an extension cord is necessary, ensure the connection is
watertight and dust proof. A cord with a proper rating should be
used. A cord rated for less amperes or watts than the appliance
rating may overheat. Care should be taken to arrange the cord so
that it will not be tripped over or pulled. The connection should
be carried out by a qualified electrical installer.
9. Indoor Household Use Only. Not for commercial use.
10. Do Not attempt to open rear of appliance. No User serviceable parts
inside. Refer all repairs to a qualified electrician or HVAC specialist.
SAvE THESE INSTRUCTIONS.
Initial Set-up
This will need to be performed BEFORE placing eggs in the incubator!
1. Fill the water tray. Use the slide out tray in the bottom
of the unit to add humidity to the environment.
Keep this tray filled with water throughout
the incubation period to provide humidity.
Since evaporation depends on the
temperature it is advisable to check
the water on a daily basis. Place a
deeper container with water
in the incubator if
daily checks
are not
possible.
replacement part.
®
2. Set the temperature. Use the 'up arrow' or 'down arrow' buttons
located on the front panel to adjust to incubation temperature. The
'up arrow' button increases the temperature, the 'down arrow"
button will decrease the temperature. The unit will automatically
switch to heating or cooling mode based on the set incubation
temperature.
Important
The temperature display and the setting is an approximate value
and does not 100% represent the actual temperature inside the
unit as the sensor is not directly placed in the incubation area. The
difference between the actual temperature in the incubation area
and the reading on the display depends on the ambient temperature
in the room where the unit is placed. These differences can also vary
depending on the set temperature, the higher the set temperature,
the bigger the variance. Please note that there is also a temperature
variation between the top and the bottom of the unit, with the
digital readout reflecting the uppermost temperature. Monitor this
temperature over a period of 24 hours with a separate thermometer
(optional) to ensure the unit is set and working properly. It is also
recommended to check the temperature at each location of the
incubating eggs.
Temperature deviations shown on the display and the actual setting
are normal. This is due to the functioning of the device as it switches
with a delay of +/- 2°C(3.6°F.) At a setting of 32°C the device will
start heating when the temperature falls to 30°C or 86°F on the
display, and starts cooling when the temperature reaches 34°C or
93.2°F. When using closed boxes or deli cups, the breeding substrate
in it will not vary more then 0.2°C, ensuring a constant incubation
temperature.
Always have the unit operating for a few days to monitor
temperatures before placing the eggs inside of the incubator.
Regular temperature checks are required with a separate calibrated
thermometer as we do not accept ANY claims for loss of eggs or
animals due to the malfunctioning of the unit.