Preparation of MISTRAL PREMIUM; SYSTEM
• Remove MISTRAL from the packaging.
• Loosen the screws (3) and open the cover of the connection housing (2) .
• Loosen the cable gland for the power supply (5) .
• If needed, loosen the cable gland for interface (6) .
Installation
• The device may only be installed by a trained technician.
• The surrounding temperature may not be higher than 65 °C
• The installation must ensure that
– only cold air is taken in.
– no (warm air) back pressure arises.
– the device is not exposed to the flow of hot air from another device.
• Protect MISTRAL against mechanical vibrations and shocks.
• Attach MISTRAL with four screws Ø M4 to the mounting tabs (1) .
• Avoid positioning the device perpendicularly. If a perpendicular position is absolutely necessary, make sure
device can cool off – Overheating risk.
• For installation dimensions, see page 3 (Size)
• If the air contains dust use a Leister stainless steel filter (see accessories) and push it on the Connection ø
38 for air hose or stainless steel filter (8).
• In the case of particularly critical dusts (e.g. metal, electrically conductive or damp dusts), special filters must
beused to avoid short-circuits in the device.
The local standards and guidelines that apply must always be observed during installation (e.g. special
fire protection guidelines, etc.).
26
Caution: Always operate the device with air supply!