8. TROUBLESHOOTING
SYMPTOM
CAUSE
Unit does
- Power cut.
not work.
- The plug has been
plugged inproperly.
- The full-tank indicator
is ON. Tank is full.
- Current leaking or
pressing test button
of LCDI plug.
Unit sud-
- The indoor tempera-
denly stops
ture has reached the
during in
set temperature level.
operation.
- The preset time is up.
- The full-tank indicator
is ON. Tank is full.
Unit runs in-
- Malfunction.
termittently.
- Surrounding temper-
ature is too high or
too low.
- Exhaust duct hose is
blocked.
Unit func-
- Window or door is
tions but the
left open in the room.
room is not
- There is heat source
cooled.
in the room or too
many of people in it.
- Air intake grille is
clogged.
- Filter is too dirty.
- Temperature setting
is too high.
Condensed
- The tank is nearly full.
water is
spilled out
when mov-
ing the unit.

BEFORE CALLING FOR SERVICE

The following are not defects.
A hissing noise or hollow
e
sound :
e
A squeaking noise :
e
Odor :
The unit does not start nor
e
change operation mode
immediately :
e See "Filter Cleaning Indicator",
Blue LED flashes :
The unit does not receive
e
signal from the remote
control.
SOLUTION
- Wait for power to be
supplied again.
- Plug in again.
- Remove the drain
water from the drain
tank.
- Press reset button af-
ter solving the prob-
lem.
- Reset the tempera-
ture level.
- Reset the timer.
- Remove the drain
water from the drain
tank.
- Contact your dealer.
- Check the duct hose.
- Close all windows
and door.
- Move out any heat
source in the room.
- Clean the air intake
grille.
- Replace the filter.
- Lower the tempera-
ture setting.
- Remove the drain
plug on the rear bot-
tom of the unit, drain
off the water then the
unit will be in opera-
tion automatically.
This sound is generated from
the refrigerant flowing within
pipes.
This noise is generated from the
unit when it is expands or con-
tracts with temperature changes.
Such odor as tobacco, cosmetics,
or foods may accumulate in the
unit.
To prevent overloading the com-
pressor motor, the unit will be
stopped for more than 3 minutes.
Page 3.
See "Synchronizing Frequency of
Remote Control with Unit", Page
2.
9. SPECIFICATIONS
MODEL
COOLING CAPACITY
HEATING CAPACITY (TAD-T32JW only)
DEHUMIDIFYING CAPACITY
POWER SOURCE
POWER CONSUMPTION
OPERATING CURRENT
AIR FLOW (MAX.)
OPERATING TEMP. RANGE
DIMENSIONS (W × H × D)
WEIGHT
COMPRESSOR
REFRIGERANT
NOTE: Cooling capacity will vary according to temperature and
humidity of the room.
10. VENTING KIT ACCESSORIES
If the unit is to be used exclusively in one space, the cooling ef-
ficiency will be enhanced by using the following venting kit ac-
cessories.
EXHAUST DUCT SET (FLEXIBLE TUBE) (Fig. I)
2 pcs.
Max. 4 ft. (1.2 m)
WINDOW PANEL KIT "C" (Fig. J)
Window panel kit "C"
For sliding and double-hung windows
Max. 37 in. (94 cm)
Min. 28-1/4 in. (72 cm)
USING EXHAUST DUCT SET (Fig. I)
1. Extend one-side ends of the exhaust
duct hose (flexible tube) (I2) around 4
in. (100mm).
2. Insert both ends of exhaust duct hose
(flexible tube) (I2) into exhaust duct
hose adapter nozzles (I1) by twisting
clockwise until it stops.
3. Fix one of the exhaust duct hose adapter noz-
zles onto the rear outlet of the unit. This is
completed by sliding the exhaust duct hose
adapter nozzle of the hose downwards over
the exhaust outlet of the unit, which will be
assembled with the grooves on the connector
of the unit. (B5 or B9)
4. Extend the exhaust duct hose (I2) and close the window or
door as far as possible trapping the exhaust duct hose
adapter nozzle (I1).
NOTE: Place the unit as close as possible to the window or
door.
USING WINDOW PANEL KIT (Fig. J)
NOTE: Window installations are possible by the use of the ex-
haust duct set and window panel kit.
In case of twin duct type, always use the window panel
kit "C".
1. Fix the exhaust duct hose grille (J3) to the window panel
with four (4) screws. Make sure that the panel is extended so
that screws do not go into sliding portion of panel.
4
ENGLISH
TAD-T38J / TAD-T32JW
13,000 / 12,000 BTU/H
11,000 BTU/H
0.58 gal/h (2.2 L/H)
Single Phase 115V, 60Hz
1,185 W
10.5 A / 8.5 A (Heating)
250 CFM (425 m
3
/h)
64˚F~95˚F (18˚C~35˚C)
20" × 36" × 16-1/2"
(508 × 915 × 418 mm)
84 Lbs. (38 kg)
ROTARY
R-410A
4 in.