5 Torch handle control elements

5 Torch handle control elements
NOTICE
• Only qualified personnel are permitted to perform work on the device or system.
• Consult the documentation for the welding components.
Using a standard welding torch, the two-cycle mode of the trigger can be activated.
5.1 Trigger 2-cycle function
1 Press the trigger on the handle and keep it pressed = welding is started.
2 Release the trigger = welding is stopped.
6 Operation
WARNING
Electric shock
Equipment parts are energized in the enterprise.
• Do not reach into the danger zone.
1 Open the shielding gas cylinder and start the welding process.
2 After ignition, hold the welding arc near the surface of the material to be welded until a
molten pool is formed.
3 Move the torch uniformly over the entire seam length.
4 Stop the welding process.
5 After switching off, hold the torch over the end position for a few seconds. This allows the
molten pool to solidify without atmospheric interference under the protection of the gas
which is continuing to flow.

7 Putting out of operation

NOTICE
• When decommissioning the system, ensure that the procedures for switching off the
welding components are observed.
• As liquid-cooled cable assemblies start to leak when they overheat, the coolant
recirculator should continue running for approx. 5 min. after welding.
1 Switch off power supply.
2 Close the valve of the shielding gas cylinder.
EN - 10
®