Troubleshooting; Technical Specifications; Electrical Wiring; Compliance - Buffalo G781 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
UK

Troubleshooting

If your BUFFALO appliance develops a fault, please check the following table before making a call to the
Helpline.
Fault
The appliance is not working

Technical Specifications

Model
Voltage
G781
230V 50Hz

Electrical Wiring

The plug is to be connected to a suitable mains socket.
This appliance is wired as follows:
Live wire (coloured brown) to terminal marked L
Neutral wire (coloured blue) to terminal marked N
Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency
disconnection being required they must be readily accessible.

Compliance

The WEEE logo on this product or its documentation indicates that the product must
not be disposed of as household waste. To help prevent possible harm to human
health and/or the environment, the product must be disposed of in an approved and
environmentally safe recycling process. For further information on how to dispose of
this product correctly, contact the product supplier, or the local authority responsible
for waste disposal in your area.
BUFFALO parts have undergone strict product testing in order to comply with
regulatory standards and specifications set by international, independent, and federal
authorities.
BUFFALO products have been approved to carry the following symbol:
All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means,
electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of BUFFALO.
Every effort is made to ensure all details are correct at the time of going to press, however, BUFFALO reserve the
3
All manuals and user guides at all-guides.com
Probable Cause
The appliance is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Power
Current
180W
0.75A
right to change specifications without notice.
Action
Check the appliance is plugged in correctly
and switched on
Call BUFFALO agent or qualified technician
Replace the plug fuse
Check power supply
Call BUFFALO agent or qualified technician
Dimensions h x w x d (mm)
428 x 210 x 320
Weight (kg)
5.5kg

Publicité

Table des Matières
loading

Table des Matières