4.2- S et up and preparation for operation
4.2.1- For PREHLS52 / 042001 ; PREHLS52/5 / 042031 and PREHLS7T / 042011
Bolt the Support Leg to the Log Splitter.
Lift the log splitter by the handles at both ends and place it on a 60 - 75cm high, stable, flat and level
work surface.
4.2.2- For PREHLS7T/V / 042021
1. Pull Spring Pin (A) to remove the Lock Pin (B). (see fig.6)
Apply a thin coat of grease (1) to both surfaces of the Control Lever Guard as illustrated.
Insert the Control Lever and Guard Assembly and make sure the Control Lever End goes into the slot
of Connection Bracket (C).
Lock the Control Lever and Guard Assembly down with the Lock Pin (B) and Spring Pin (A).
Follow the same steps to install the other Control Lever and Guard Assembly on the other side.
2. There are 3 installation positions (fig.7) available for the Support Table for different splitting
length.
At every installation positions, Lock Down Hooks (D) are available.
Insert the Support Table in the selected Brackets (E).
Turn the Lock Down Hooks (D) on both side by 90 degrees to lock the Support Table down.
Fig.6 : (1) apply grease
Fig.7
4.3- Electrical requirements
4.3.1- For PREHLS52 / 042001; PREHLS52/5 / 042031 and PREHLS7T / 042011
Connect the main plug to a standard 230V±10% (50Hz±1Hz) electrical supply fitted with a protection
devices of under-voltage, over-voltage, over-current as well as a residual current device (RCD),
which maximum residual current rated at 0.03A
Wiring and Plumbing diagrams (Figs.8a&b; Fig. 9):
4.3.2- For PREHLS7T/V / 042021
With 230V 50Hz motor, the log splitter should be connected to standard 230V±10% (50Hz±1Hz).
The electrical supply must be fitted with protection devices of under-voltage, over-voltage, and
over-current as well as a residual current device (RCD), which maximum residual current rated at
0.03A.
Electrical connection rubber cables must comply with EN60245 which are always marked with
H07RN.
Wiring and Plumbing diagrams (Fig.10):