TROUBLESHOOTING
Fault
Light on, but
motor does not
work
Light does not
work, motor does
not work
Oil leakage
Lights not
working
Insufficient
suction
The Cooker hood
inclines
NOTE:
Any electrical repairs to this appliance must conform to your local, state and
federal laws.Please contact the service centre if in any doubt before
undertaking any of the above.Always disconnect the unit from the power source when
opening the unit.
MAINTENANCE AND CLEANING
Caution:
• Before maintenance or cleaning is carried out, the cooker hood
should be disconnected from the main power supply. Ensure
that the cooker hood is switched off at the wall socket and the
plug removed.
•
External surfaces are susceptible to scratches and abrasions, so please follow the
cleaning instructions to ensure the best possible result is achieved without damage.
Possible Cause
Fan switch turned off
Fan switch failed
Motor failed
House fuses blown
Power cord loose or
disconnected
One way valve and the outlet
are not tightly sealed
Leakage from the connection
of chimney and cover
Broken/Faulty globes
The distance between the
cooker hood and the gas top
is too far
The fixing screw not tight
enough
Select a fan switch position.
Contact service center.
Contact service center.
Reset/Replace fuses.
Refit cord to power outlet.
Switch power outlet on.
Take down the one way valve
and seal with sealant.
Take chimney down and seal.
Replace globes as per this
instruction.
Refit the cooker hood to the
correct distance.
Tighten the hanging screw
and make it horizontal.
8
Solution