Technical Data - Scheppach HWW1300 Traduction Des Instructions D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
• The pump must not be used for swim-
ming pool operation.
• The pump must not be installed in the
drinking water circuit.
Remaining hazards
The machine has been built using
modern technology in accordance
with recognized safety rules. Some
remaining hazards, however, may still
exist.
• Injury through electric current if incor-
rect electric connection leads are used.
• Even when all safety measures are tak-
en, some remaining hazards which are
not yet evident may still be present.
• Remaining hazards can be minimized
by following the safety instructions as
well as the instructions in the chapter
Authorized use and in the entire oper-
ating manual.
• Health hazard due to electrical power,
with the use of improper electrical con-
nection cables.
• Release the handle button and switch
off the machine prior to any operations.
• Avoid accidental starts of the machine:
Do not press the start button while in-
serting the plug into the socket.
• Use the tools recommended in this
manual to obtain the best results from
your machine.
• Always keep hands away from the work
area when the machine is running.
24 | GB
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
Warning! This electric tool generates
an electromagnetic field during opera-
tion. This field can impair active or pas-
sive medical implants under certain con-
ditions. In order to prevent the risk of se-
rious or deadly injuries, we recommend
that persons with medical implants con-
sult with their physician and the manufac-
turer of the medical implant prior to oper-
ating the electric tool.

6. Technical data

Dimensions L x
B x H
Mains connection
Power rating
Max. delivery rate
Particle size
Boiler contents
Max. delivery
head
Max. delivery
pressure
Max. suction
height
Pressure and
suction connector
Max. water
temperature
Protection class
Protection type
Operating mode*
Weight
Subject to technical changes!
Operating mode* S1: Continuous opera-
tion at constant load
440 x 280 x 580
mm
230V~ / 50 Hz
1100 W
4200 l/h
1 mm
24 l
50 m
5 bar
8 m
G1"
35°C
I
IPX4
S1
14,2 kg