When the level of water in the compensation tank reaches the
maximum level switch, current is cut to the filling solenoid valve
of the water mains. The operating level has been reached.
NOTE: during use of the spa and with the filtering pump in op-
eration, if the level of water does not reach the overflow chan-
nel (for example when people are getting out), the return-fil-
tering line automatically refills this level, taking water from the
compensation tank. If the level of water in the compensation
tank drops below the minimum level switch, it will give the sig-
nal to fill water back up to maximum level, using the filling so-
lenoid valve of the tub.
Also refer to the chapter on setting the general system parame-
ters for information on the activation time of the solenoid valve.
Start water heating using the control panel or the pneumatic
push button installed at the tub. If the water temperature is lower
than that programmed, the heating system will start automatically.
Start the hydromassage via the pneumatic push button(s) in-
stalled at the tub. If you press the button(s) again, the pumps will
stop (refer to corresponding chapter).
If installed, check operation of the blowers by pressing the p-
neumatic push button installed near the tub (refer to corre-
sponding chapter).
Check that the spotlights switch on and off by pressing the
pneumatic push button installed near the tub (refer to corre-
sponding chapter).
Carry out a super-chlorination treatment (shock treatment) as
set forth in the chapter on water treatment.
NOTES
- to activate the filtering pump, the hydromassage and the
spotlights using the pneumatic push buttons, they must first
be activated using the control panel on the electrical box. Re-
fer to the corresponding chapters for this operation.
Also refer to the specific chapter on setting the temperature.

WARNINGS

PLEASE CAREFULLY READ
THE FOLLOWING WARNINGS.
Jacuzzi Europe S.p.A. accepts no liability for
damages arising from failure to observe the fol-
lowing directions.
Do not use the water at temperatures over 40°C.
Temperatures between 38°C and 40°C are normally tolerated
by adults but the ideal temperature is 35-36°C.
Carefully check the water temperature, which must not ex-
ceed 40 °C .
Tolerability to hot water varies from person to person.
Pregnant women and small children must not use the spa
without first consulting a doctor; in any case the water tem-
perature must have a temperature of less than 38°C.
Be very careful if you are alone when using the spa. Pro-
longed immersion in warm water may cause nausea, dizzi-
ness and fainting. If you intend to use the spa for more than
10-15 minutes, a lower water temperature must be set. This
applies also to children.
Persons with heart conditions, diabetes, high or low
blood pressure or other health problems must not use
the spa without first consulting their doctor.
Do not use the spa after drinking alcohol, taking drugs
or medicines that cause drowsiness or that can
raise/lower the blood pressure.
Persons under medical care must consult a doctor before
using the spa as some medicines can cause drowsiness,
affect the heartbeat, blood pressure and circulation.
Be especially careful when getting in and out of the spa
when the floor is wet.
Electrical appliances (radios, hair dryers etc.) must not
be used near the spa.
During use of the spa, keep your head, body and clothes
at a distance of at least 40 cm from the suction intakes;
long hair must be tied back and secured in place.
Do not start the spa if the protective grilles are broken or
missing. Contact an authorised Jacuzzi
thorised Service Centre.
Only use original spare parts.