Connecting the Power Supply - Indoor Models
1 . Route the plug-in transformer cable through the small hole
provided in the bottom of the cabinet .
2 . Tie a knot in the cable to provide a strain relief, and connect the
wires to the terminals labeled "24 VAC" (in either order) .
3 . Close the control module and plug the transformer into a wall outlet .
The controller is now ready to program and operate .
Note: To immediately test-run the Rain Dial-R irrigation control
system, refer to the "Controller Station Test Feature" on page 17.
Figure 8
EARTH
GROUND
1
24 VAC
7
8
9 10 11 12
VC
+
2
3
4
5
6
MV/
Pump
Sensor
Strain-relief
Knot
-
24 VAC, 30VA
Transformer
15