Note:
① Air function is only effective for units with air function and fresh air motorized air
valve (abbr. fresh air valve).
② The following table indicates the opening time of fresh air valve per unit of time
(60min) corresponding to the level of Air setting. Opening time of fresh air valve is
the initial N minutes per unit of time. Example: The level of Air setting is set to 1,
then unit starts timing and fresh air valve is open. 6 minutes later, fresh air valve is
closed and unit keeps running. After timing for 60minutes, unit restarts timing and
fresh air valve is open again. 6 minutes later, the valve is closed and the cycle
repeats.
Level of
1
Air setting
Opening
time of
60
fresh air
/6
valve
Note: time indicated in the table: unit's operating time (min) / opening time of fresh air
valve per operating time (min)
3.10 LIGHT ON/OFF SETTING
Light On/Off Function: Light of indoor unit can be turned on or off.
Turn on the Light: When unit is on or off, press FUNCTION button to select Light
function."
" icon will blink. Press ENTER/CANCEL to turn on the light
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.
Fig.4.6 Turn on Air Function
2
3
4
60
60
60
/12
/18
/24
Press ENTER/CANCEL button to turn on Air function
5
6
7
60
60
60
/30
/36
/42
29
Wired Controller XK46
8
9
60
60
Always
/48
/54
10
on