Wired Controller XK46
No.
Panel of wired
Name
controller
Q'ty

3.1 INSTALLATION OF WIRED CONTROLLER

3.1.1 Communication Line Selection

communication line
Wire material
between indoor unit
type
and wired controller
Light/Ordinary
Polyvinyl
chloride
sheathed
cord.
(60227 IEC 52
/60227 IEC
53)
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.
1
Self-tapping Screw ST3.9X25
1
Fig. 3.2 Length of communication line
Total length of
Wire size
(mm
L (m/feet)
L≤250m
1.25 mm
(L≤820-1/5feet)
(2×AWG1
8~2×AWG
2
MA
3
Material
2
/AW
standard
G)
2×0.75
2
mm
~2×
IEC
2
60227-5:2
007
16)
8
3
Soleplate of wired
controller
1
Remarks
(1)Total length of
communication line can't
exceed 250m (820-1/5feet).
(2)The cord shall be Circular
cord (the cores shall be
twisted together).
(3)If unit is installed in
places with intense
magnetic field or strong
interference, it is necessary
to use shielded wire.