Télécharger Imprimer la page

Axis Q16 Serie Mode D'emploi page 29

Masquer les pouces Voir aussi pour Q16 Serie:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
Function
Pin
1
DC ground
2
DC output
3–
Configurable
6
(Input or
Output)
Example
1
DC ground
2
DC output 12 V, max 50 mA
3
I/O configured as input
4
I/O configured as output
5
Configurable I/O
6
Configurable I/O
AXIS Q16 Network Camera Series
Notes
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Digital input – Connect to pin 1 to activate, or
leave floating (unconnected) to deactivate.
Digital output – Internally connected to pin 1 (DC
ground) when active, and floating (unconnected)
when inactive. If used with an inductive load, e.g.,
a relay, connect a diode in parallel with the load,
to protect against voltage transients.
29
Specifications
0 V DC
12 V DC
Max load = 50 mA
0 to max 30 V DC
0 to max 30 V DC,
open drain, 100 mA
EN

Publicité

loading

Ce manuel est également adapté pour:

Q1645-leS q1647-le