14. The LED sequence will remain the same, solid for stopped and fast for moving
15. Once at the bottom floor, the Navigation box LED will show that it is complete
by flashing a slow green colour. If the colour remains orange or red the try the
Nav learn again starting from point 5. If the problem persists please contact Avire
Technical support.
16. Finally, turn dip switch 3 off and mount the Navigation box on top of the car
connected to the CANbus coming from the DCP
Mounting
1.
Ensure the wiring looms have been connected correctly (as per diagram above)
2.
Power up the system by turning on the DCP or connecting DCP to mains (the
Navigation box runs off the CANbus wiring from the DCP). Mount the Navigation
box on top of elevator car
3.
Fasten Navigation box to position using mounting holes
4.
Wire the Navigation box to the relevant devices e.g. E-Motive PRP or DCP paying
particular attention to polarity of power and CANBus connections of each of the
devices.
5.
Ensure cabling is run securely away from any moving devices and sharp edges
6.
Take the car to the bottom floor and turn down switch 3. The LED will start flashing
red indicating sensor initialization and then green for operational mode.
4-wire CANbus`