pump this way, before starting it, take it to a warm environment for long enough to melt any ice inside. Fail-
ure to do so could cause serious damage to the motor pump.
Warning
The rinsing fluids and the antifreeze liquid must be suitably disposed of and not discarded in the envi-
ronment.
Maintenance
Warning
Follow the maintenance instructions contained in the manual of the machine in which the motor
pump is integrated.
• All maintenance jobs must only be performed after carrying out the operations described in the "stop" par-
agraph, meaning without any moving parts, no pipe full of liquid under pressure and only after com-
plete cooling.
In particular, remember to always disconnect the power supply.
• Any maintenance jobs must be performed in conditions of total stability.
• WARNING. To ensure the safety of the motor pump, only use original spare parts supplied by the Manufac-
turer or approved by it.
Routine maintenance
Perform the routine maintenance jobs shown in the manual of the machine in which the motor pump is
integrated; unless otherwise indicated, in relation to the motor pump, remember the following.
ROUTINE MAINTENANCE
After every use.
Every 50 hours.
Checks must be made more frequently if the motor pump operates where there are strong vibrations.
(1)
English language
GENERAL INFORMATION - PART ONE
• Check and if necessary clean the suction filter.
• Check any power cable, high-pressure pipes and clamp
tightness.
In the event of one or more parts being damaged, do not use
the machine and contact a Skilled Technician.
• Check the integrity of the suction circuit.
• Check the fastening of the motor pump to the structure of the
machine in which it is integrated.
In the event of such fastening being unstable, do not use the
machine and contact a Skilled Technician (1).
46
JOB
Use and Installation
1