Specifications

Install DR90 according to National Electric Codes.
Dry-Bulb Temp
80°F (26.7°C)
70°F (21.1°C)
60°F (15.6°C)
Home Size
(square ft [m])
2080 (193.2)
2600 (241.5)
3120 (289.9)
* Based on extreme climates where outdoor humidity is 70-90% RH. For less extreme climates, larger
homes can be adequately served with less capacity. Actual requirements may vary.
Dimensions in inches and (mm):
14 3/8 (365)
21 9/32
(541)
Product weight: 92.2 lbs. (41.8 kg)
Shipping weight: 102 lbs. (46.3 kg)
Shipping dimensions: 21.5 in. H x 18.5 in. W x 40.2 in. L
Media Filter: MERV 11, 13.75 in. H x 13.75 in. W x .75 in. D
Drain connection: 3/4-in. threaded female NPT connection,
with attached 3/4-in. male connection.
Duct connections: 10-in. round inlet and outlet. 6-in. supply
inlet. ABS plastic, compatible for connection to rigid or
flexible ducting with sheet metal screws and/or tape.
Cabinet: 20 gauge galvanized steel powder-coat painted.
Insulation: R value 1
Compressor: Rotary-style, 6.8 KBTU
Refrigerant: R-410A, 1.0 lbs.
Operating Temp Range (outside cabinet):
34ºF to 135ºF (1.1ºC to 57.2ºC)
Operating Humidity Range: 0-99% RH
4
Intake Humidity
Capacity (Pints/Day)
60% RH
60% RH
60% RH
Dehumidifier Capacity Required to Maintain Desired Indoor RH*
60% RH Indoor
(pints/day)
49–54
61–68
75–82
3 3/16
(81)
33 7/16 (849)
90
77
47
50% RH Indoor
(pints/day)
55–58
65–72
79–86
Airflow versus external static
pressure (0–1 in. [0 - 25.4 mm] water
3 3/16
(81)
pressure) with collars attached
0 in. (0 mm)
0.2 in. (5 mm)
0.4 in. (10 mm)
0.6 in. (15.2 mm)
M28840
Input ratings
• Electrical input voltage: 120 VAC,
• Input current: 6.7 amps
Output ratings
• Power transformer to R/C
• Energy Performance: 2.5 liters
Standards and approval body
requirements
ETL Tested per standard UL 474 ducted
dehumidifier.
ENERGY STAR rated.
40% RH Indoor
(pints/day)
71–78
90–97
95–110
235 CFM
210 CFM
195 CFM
175 CFM
60 Hz nominal
terminals: 24 VAC, 0.85 A
(5.3 pints) per kilowatt hour (KWH)