Sirius SLT950 Instructions D'utilisation Et Avis De Montage page 13

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
For proper working, it is recommended to in-
stall the appliance at a distance of 2000
- 2100 mm from the floor.
Before starting the appliance installation,
please check that all components are not da-
maged,
in such a case contact your retailer and do not
carry out installation.
Furthermore, please read carefully all of the
following installation instructions.
- Use an exhausting pipe whose maximum
length does not exceed 5 meters.
- Limit the no. of elbows in the piping, since
each elbow reduces the air capacity
of 1 linear meter. (Ex.: if you use no. 2 x 90 °
elbows, the length of piping must not exceed
3 meters).
- Avoid abrupt direction changes.
- Use a 150/200 mm constant diameter pipe
for the whole length.
- Use piping approved by standards in force.
INSTALLATION
SLT950 EM – SLT951 EM-SLT 952 EM – SLT953
EM - SLT958 EM.
Fit a false ceiling with an opening of the fol-
lowing sizes:
SLT950 EM: 1465x965 mm with a minimum
distance of 270 mm between the ceiling and
the false ceiling;
SLT951 EM: 1065x665 mm with a minimum
distance of 270 mm between the ceiling and
the false ceiling.
SLT952 EM: 1050x645 mm with a minimum
distance of 250 mm between the ceiling and
the false ceiling;
SLT953 EM: 1065x665 mm with a minimum
distance of 270 mm between the ceiling and
the false ceiling.
SLT958 EM: 865x405 mm with a minimum
distance of 270 mm between the ceiling and
the false ceiling.
It is possible to select the side of the hood
where the air suctioned can be discharged.
After having chosen the most suitable posi-
tion, prepare the ducting: an air outlet con-
nection piece, with a diameter of 150 mm to
be installed in the side selected, is provided
with the appliance.
Leave any unused exhaust outlets closed.
Draw the outline of the hole to house the cei-
ling-mounted hood on the solid ceiling (Fig.
1), according to the model chosen; make 4
holes in the ceiling according to the dimen-
sions shown in (Fig. 2); place the metric plugs
provided in the holes.
Open the stainless steel panels, following
the instructions mentioned in the USES sec-
tion, and remove the grease filters in order
to avoid damaging them in any way and too
allow installation (Fig. 3); screw the threa-
ded bars provided into the plugs (Fig.4); the
threaded bars are 250 mm long and serve to
install the ceiling-mounted hood at a distan-
ce from the solid ceiling of between 270 mm
and 370 mm (Fig. 5); in case of a larger gap
between the hood and the ceiling, you need
to use longer threaded bars.
13