4.2 RECOMMENDED NOZZLES
CRONO 10-L2, 15-L2 and 20-L2
Delavan type W - E; Monarch type R
Steinen type Q
; Satronic type S
Danfoss type S
4.3 MAINTENANCE POSITION
CRONO 10-L2, 15-L2 and 20-L2
To fit nozzle carry out the following actions:
(see fig. 12).
Remove nozzle-holder assembly (1) after loosing
screws (2) and nut (3), remove the small cables (4)
from the control box and the photoresistance (5).
Withdraw the small cables (4) from the electrodes,
remove the diffuser disc-holder assembly (8) from
the nozzle-holder assembly (1) after loosing screw
(3, fig. 15, pag. 9) .
Screw the nozzle (9) correctly and tighten it as
shown in figure.
Fig. 12
2701
CRONO 25-L2
Delavan type W - B; Steinen type Q; Danfoss type S.
N.B.: If necessary the 1
output exceeding 50 % of the total output.
To fit nozzle carry out the following actions:
(see fig. 13).
Remove nozzle-holder assembly (1) after loosing
screws (2) and nuts (3), remove the small cables
(4) from the control box and the photoresistance
(5).
Withdraw the small cables (4) from the elec-
trodes, remove the diffuser disc assembly (8)
from the nozzle-holder assembly (1) after loosing
screws (9).
Screw the nozzles (10) correctly and tighten it as
Fig. 13
2
4
3
5
0 2 4 6 8
S7238
9
GB
st
stage nozzle can have an
CRONO 25-L2
6
8
10
7
1
9
S7118