GB
The measured sound pressure level measured in a free range at
distance of 1 m: ±3dB(A) at the maximum working pressure. (table
3)
SERIE F
HP/kW
1/0.75
1.5/1.1
1.5/1.1
2/1.5
SERIE FB
HP/kW
2/1.5
SERIE GSM
HP/kW
0.75/0.55
1.5/1.1
1.5/1.1
SERIE VS
HP/kW
2/1.5
2/1.5
3/2.2
The value of the sound level may increase from 1 to 10 dB(A)
depending on the room in which the compressor is installed.
Note: The electric compressors on wheels with power greater then or
equal to 3 Hp are intended for indoor use.
HINTS FOR EFFICIENT OPERATION AIRCLIK / F 1
THE F1 & AIRCLICK COMPRESSORS HAVE BEEN DESIGNED
FOR INTERMITTENT USE, THESE MODELS SHOULD ONLY BE
USED FOR APPLICATIONS WHERE USAGE WILL NOT
EXCEED 25% OF DUTY OVER THE COURSE OF ONE HOUR.
PNEUMATIC CONNECTIONS
Make sure you always use pneumatic tubes for compressed
with maximum pressure characteristics that are adequate for
compressor.
Do not attempt to repair tubes if
WE RESERVE THE RIGHT TO MAKE ANY MODIFICATIONS
WITHOUT PRIOR NOTICE WHENEVER NECESSARY
a
RPM
Db(A)
1450-1750
65
2850
77
3450
80
2850
78
RPM
Db(A)
1450
67
RPM
Db(A)
1450/1750
77
1450/1750
77
2850
78
RPM
Db(A)
1450
77
1750
80
2850
82
air
the
faulty.
18