Measured Fill Calibration

30
Measured Fill Calibration
The accuracy of your Measured Fill function can be affected by variations in the incoming water
pressure. The Measured Fill Calibration Mode allows you to fine-tune the amount of water
dispensed from the preselected volumes on your cabinet.
The calibration mode is worked out as a percentage. You can measure the amount the refrigerator is
under filling or over filling and increase or decrease the calibration to get the exact amount you want.
To assess whether the Measured Fill function is under or over filling:
Press the
Dispense this amount into a measuring jug.
Estimate the amount of water that has been dispensed into the jug.
eg. 31 floz = under filling by 1 floz or 975 ml = under filling by 25 mls
To calculate the Calibration factor:
Transfer the difference into a percentage.
eg. 32/31 = 1.03 = 103% or 1000/975 = 1.03 = 103%
Enter the Calibration mode by pressing and holding the
100CAL will be displayed.
The number displayed is a percentage. Adjust this accordingly using the
eg. 100 CAL = 103 CAL
Press the
Please note:
The Measured Fill function has an accuracy of +/-5% at the time of calibration.
The accuracy of your calibration will of course be subject to the accuracy of your measuring
device and method.
Calibration quick reference guides
US
Actual amount of
water received
Underfilling – you dispense 1 qt but the amount of water you receive is actually less than 1 qt
31 floz
30 floz
Overfilling – you dispense 1 qt but the amount of water you receive is actually more than 1 qt
33 floz
34 floz
Metric
Actual amount of
water received
Underfilling – you dispense 1 L but the amount of water you receive is actually less than 1 L
975 ml
950 ml
Overfilling – you dispense 1 L but the amount of water you receive is actually more than 1 L
1025 ml
1050 ml
button until 1 qt (1 L) is displayed.
button to confirm your selection.
Difference from
Under filled
1 floz
2 floz
1 floz
2 floz
Under filled
25 ml
50 ml
25 ml
50 ml
and
buttons together for 4 seconds.
32 floz
3%
7%
3%
6%
Difference from
1 L
3%
5%
2%
5%
and
buttons.
Adjust display to read
(calibration factor)
103 CAL
107 CAL
97 CAL
94 CAL
Adjust display to read
(calibration factor)
103 CAL
105 CAL
98 CAL
95 CAL