INSTALLATION INSTRUCTIONS
PROUD INSTALLATION
SPECIFICATIONS
The cabinet depth from the outer edge of the face frame to the inside back of the cabinet or wall should be at
least 24 3/16" inches (see figure 02A).
The Warming Drawer should be installed into a base cabinet with minimum outside dimensions of 18 1/2" high by
31" wide by 24 3/16" deep (see figures 03A & 04A).
Power supply required: 120 VAC; 15 amp GFI (Ground Fault Interrupt) circuit
CUTOUT DIMENSIONS
2-1/2" min. to
bottom of
countertop
14-11/16"
(372mm)
28 3/8"
(720mm)
30"
Fig. 03A
23 1/4" (590mm)
1 1/8" (28mm)
26 1/8" (663mm)
24 1/8" (613mm)
2-1/2" min. to
bottom of
countertop
14-11/16"
(372mm)
28 3/8"
(720mm)
A 120 Volt AC (GFI)
outlet should be
located below the
Warming Drawer
2x4's or similar
support
24 3/16" (614mm) min. cabinet depth
Fig. 02A
28 3/8"
(720mm)
PROUD
1 7/8"
1 7/8"
1 1/8" (28mm)
(47mm)
(47mm)
21 1/8"
Position supporting boards as shown so
(537mm)
product can be secured into position.
16"
1"(25mm)
7
Electrical
outlet
11-11/16"
14 -7/16"
(297mm)
(367mm)
A 120 Volt AC (GFI)
outlet should be
located below the
Warming Drawer
2x4's or similar
support
24 3/16" (614mm) min. cabinet depth
28 3/8"
(720mm)
PROUD
1 7/8"
1 7/8"
(47mm)
(47mm)
21 1/8"
Position supporting boards as shown so
(537mm)
product can be secured into position.
30"
23 1/4" (590mm)
26 1/8" (663mm)
24 1/8" (613mm)
Electrical
outlet
Installed
Drain
bracket
13/16"
(20mm)
12-1/4"
(311mm)
Fig. 04A
16"
11-11/16"
14 -7/16"
(297mm)
(367mm)
1 -5/8"
(41mm)