INSTALLATION
GAS HOOK-UP
LP TANK RESTRAINT FOR BUILT-IN INSTALLATION
If the grill is to be installed in a Built-in application, then the grill must be installed in accordance with the
Built–in installation guidelines.
If you intend to operate your Built-in grill on LP gas utilizing a 20 lb Type 1 cylinder, then the Built-in LP tank
restraint must be installed prior to initial use of the grill. If you do not have one please contact DCS Customer Care
at (888) 936-7872 for information on obtaining one.
The following steps will illustrate how to properly locate and install the LP tank restraint within the Built-in enclo-
sure.
NOTE:
The grill comes with the LP Regulator/Hose assembly installed at the factory. The assembly, along with the entire grill
system, is leak tested.
Do not remove the Regulator/Hose assembly from the grill during installation.
Center of Tank Restraint must be
placed within this area to avoid
causing stress on the LP regulator
hose connection.
The maximum distance from the center
of the manifold cut out to the center of
the tank restraint is 18 " / 45,7cm.
18" / 45,7cm max.
FIG. 24
18
Center of manifold cut
out projected to floor
of the island.