Spa water temperature is above acceptable limits.
Do not get into the spa, the water may be too hot.
I
To correct the situation:
- Remove the spa's cover and allow your spa to cool down.
- If the condition persists, contact your retailer.
"WATER IS BELOW SET-TEMP"
If the spa water temperature is 6°C lower than the set temperature
the recirculation pump and heater are automatically activated to
guarantee the anti-freezing protection. The spa remains in this mode
until the water temperature is 9°C lower than the set temperature.
I
No corrective action is required.
"COMMUNICATION ERROR"
The communication between the control panel and the elec-
tric box is defective.
I
Contact your dealer or service center.
"PUMP DOES NOT OPERATE"
Heater is deactivated; recirculation pump may also be deactivate.
Proper flow of water is obstructed or a flow switch has mal-
functioned.
Check for proper water level and for a clogged filter cartridge.
I
If there is not a noise (relative to the possible functioning of
the electro-mechanical parts) or if there is a continuous hum, dis-
connect the spa (the pump could be incorrectly primed; refer to
the "The pump does not operate" chapter).
I
Contact your dealer or service center.
"FREEZE PROTECTION"
Freezing has been noted. No intervention is necessary (this message
may appear the first time the spa is filled, seeing that the water
within the water system is often extremely cold).
I
The pump(s) and the heater function up until hazards are no
longer evident; the heater, in particular, remains active whilst
the pumps are activated for approximately 10 minutes and then
deactivated for a further 10 minutes. This cycle continues up
until hazards are no longer evident.
N.B.: in the instance where the protective function "freeze
protection" is active, it is not possible to action the pumps via the
display; if a button is pressed, the error message disappears but will
re-appear 5 minutes later (if the "freeze protection" is still active).
"EMERGENCY SHUTDOWN"
I
The water temperature exceeds the limit values.
Do not step into the spa as the water could be too hot.
I
Contact your reseller or an authorised assistance centre.
"OPEN SENSOR"
The temperature sensor is broken (the heater is deactivated).
I
Contact your reseller or an authorised assistance centre.
"SHORTED SENSOR"
The temperature sensor is broken (the heater is deactivated).
I
Contact your reseller or an authorised assistance centre.
"OPEN SENSOR"
The maximum temperature sensor does not work (the heater
is deactivated).
I
This must be repaired only by a qualified service organization.
"SHORTED SENSOR"
The maximum temperature sensor does not work (the heater
is deactivated).
I
Contact your reseller or an authorised assistance centre.
"START-UP MALFUNCTION"
CLOSE D OR SHORTE D FLOW SWITCH ON SYSTE M
STARTUP (system disabled) Flow switch is non-functional.
I
Contact your reseller or an authorised assistance centre.
Temperature symbol is flashing
Indicates that:
I
There is a difference of approximately 6 °C between the real
temperature and the set temperature or
I
The temperature sensor has read a value exceeding 44 °C, or
I
The maximum temperature sensor has read a value exceeding
46 °C.
"Please check filter" (check the filter cartridge)
6:45 PM
102
T emp.
F
Please check filter!
This message appears when the reminder for the change or
cleaning of the filtering cartridges expires.
I
Clean or replace the filter cartridge (see also relative chapter).
"Feature not installed" (option not available)
EXTERIOR
A
Feature not installed
B
This message appears when you attempt to activate an option
relative to the external lights.
I
Press the D key to cancel the message from the display.