ADVANCED USE OF AIRZONE THINK THERMOSTAT
Settings menu
This menu allows the access to the options below:
ES
Mode. For Master Think thermostats, select the operation mode for the system. (See section Operation mode).
Speed. For Master Think thermostats, select the AC unit's fan speed. (See section Fan Speed).
EN
Sleep mode. The Sleep mode is an auto power-off timer of the zone. These are the values you can select:
Off. The timing is off.
FR
30. It activates the timing and switches off the zone after 30 minutes.
60. It activates the timing. After 30 minutes, the zone varies one degree its temperature. After 60 minutes, the zone
IT
will switch off.
90. It activates the timing. After 30 minutes, the zone varies one degree its temperature. After 60 minutes, the zone
PT
varies one more degree its temperature. Finally, after 90 minutes, it switches off the zone.
Zone navigation. Access any zone of the system to change the set-point temperature, switch it on or off or see all its
DE
information.
WARNINGS AND ERRORS
The Airzone Think thermostat screenserver displays system warnings.
Warnings
Anti-freezing. It will be only displayed when it is activated. (See Section Zone Settings).
Window. It indicates the air conditioning of the zone has been deactivated due to
open window. Only available if the window contact of the system is activated.
Low battery. Low battery warning.
Incidents
If any of these errors occurs, please contact with your installer.
Error 1. Communication error with the main control board.
Error 5. Temperature sensor is opened.
Error 6. Temperature sensor is short circuited.
Error 9. Communication error between the communications gateway and the system.
Error 11. Communication error between the communications gateway and the indoor unit.
Error 13. Communication error between the main control board and the control module of radiant elements.
Error 14. Communication error with theexpansion module.
32