19
A layer of frost occurs in
the compartment
T emperature inside is
too warm
T emperature inside is
too cold
Doors can't be closed
easily
The light is not working
Check that the air outlets are not blocked by food and ensure
ventilation. Ensure that door is fully closed. T o remove the
frost, please refer to cleaning and care chapter.
You may have left the doors open too long or too frequently; or
the doors are kept open by some obstacle; or the appliance is
Increase the temperature by following the "Display controls"
chapter.
Check whether the top of the refrigerator is tilted back by
10-15mm to allow the doors to self close, or if something inside
is preventing the doors from closing.
The water pan (located at the rear bottom of the cabinet) may
not be properly leveled, or the draining spout ( located
underneath the top of the compressor depot) may not be
properly positioned to direct water into this pan, or the water
spout is blocked. You may need to pull the refrigerator away
from the wall to check the pan and spout.
The LED light may be damaged. Refer to replace LED lights
●
in cleaning and care chapter.
The control system has disabled the lights due to the door
●
being kept open too long, close and reopens the door to
reactivate the lights.
Hisense Refrigerator