INSTALLATION and Start-Up MANUAL FOR ATHENA SERIES DOSING PUMP
Your pump is part of the pump family listed in the following table:
INTRODUCTION
The dosing pump is comprised of a control unit that houses the electronics and the magnet, and a hydraulic part in
contact with the liquid to be dosed.
The parts in contact with the liquid have been chosen in order to guarantee perfect compatibility with most chemical
products normally in use. Given the range of chemical products available on the market, we recommend checking
the chemical compatibility of the dosed product and contact materials.
MATERIALS USED IN THE PUMP HEAD (STANDARD)
BODY:
CONNECTORS:
DIAPHRAGM:
BALL VALVES:
The pumps are supplied complete with the indispensable accessories for their correct installation. You will find the
following in the packaging:
Foot filter, injection valve, transparent suction tube, transparent tube for bleed valve, opaque delivery tube, Pump
fixing inserts, bracket for wall mounting, level sensor connector and instruction manuals.
EM00136156
Pressure Flow Rate
Model
bar
20
Athena 1
18
12
10
Athena 2
8
2
16
10
Athena 3
6
2
5
4
Athena 4
2
1
PVDF
PVDF
PTFE
CERAMIC
PVDF
Connections
cc /stroke.
(mm)
L/h
Int / Ext
1,5
0,21
4 / 6 – 4 / 7
2
0,28
3
0,31
4
0,42
5
0,52
8
0,83
7
0,39
10
0,55
14
0,77
16
0,88
20
1,11
22
1,22
35
1,94
50
2,77
rev. 1.1
Strokes /
min
120
4/6
160
4/6
300
8/12
300
1 Power switch
2 Regulation area
3 Dosing head
4 Priming valve
5 Delivery connector
6 Suction connector
7 Base support (optional)