OPTIONAL BLOWER INSTALLATION INSTRUCTIONS

8.
Remove three prong cord set from blower housing.
9.
Remove (4) 8 x 3/8" screws that attach blower front to blower
housing.
10. Position blower housing on top of header assembly.
11. Route 120V field wiring into blower housing through cord set
hole on back of blower housing.
12. Refer to wiring diagram to make wiring connections inside blower
housing. Be sure to follow all local and National electrical codes
when making field wiring connections.
13. Align key hole slots on back of blower housing with (2) screws
attached to wall. Position blower housing flush with wall surface
and on top of outer casing. Complete tightening blower housing
screws from Step 7 to wall.
14. Attach caps and plugs from blower housing and blower front.
15. Attach blower front to blower housing with (4) 8 x 3/8" screws
from Step 9.
16. Installation of optional blower assembly is completed.
13"
(330 mm)
Fan Control
The automatic fan control is located on the bottom of the blower
assembly. The fan control is a nonadjustable, automatic type. The
fan control will require between 3 and 7 minutes of main burner
operation before the fan control "closes" and activates the blower.
The blower will continue to run between 3 and 7 minutes after the
main burner shuts off, before the fan control "opens" and deactivates
the blower.
Page 18
4 7/16"
(112.6 mm)
Figure 3
Wiring
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical
Code, CSA C22.1, if an external electrical source is utilized. This
appliance is equipped with a three-prong [grounding] plug for
your protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do
not cut or remove the grounding prong from this plug. For an
ungrounded receptacle, an adapter, which has two prongs and a
wire for grounding, can be purchased, plugged into the ungrounded
receptacle and its wire connected to the receptacle mounting screws.
With this wire completing the ground, the appliance cord plug can
be plugged into the adapter and be electrically grounded.
CAUTION: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
Oiling
The blower motor does not have oiling holes. Do not attempt to oil
the blower motor.
GWTB2W WIRING DIAGRAM
37409-0-0616