11
Inner pipe (inserted into the outer pipe when delivered (13))
12
Height adjustment nut
13
Outer pipe
14
Pedestal cover
15
Pedestal weight
16
Pedestal locking member
17
Pedestal - locking screw
18
Protective cage - locking screw
19
Protective cage - lock
5. Assembly
Take the fan out of the package and check the device as well as the scope of deliv-
ery mentioned in the table above. Please contact the supplier if any part is missing
or has been damaged.
1. To mount the fan correctly, screw the pedestal (14, 15) first to the outer pipe
(13).
2. Take the pedestal weight (15), place the cover (14) and firmly screw the outer
pipe (13) to the pedestal (14, 15) from the bottom using the attachment (16,
17).
3. To join the motor unit (8.9) to the inner pipe (11) , insert this into the guide of
the fan control (9) and fix it using the adjusting screw (10).
4. Now place the rear protective cage (6) on the fan unit. Make sure that the
handle is facing up.
5. Tighten the rear protective cage firmly using the locking nut (5).
6. Then insert the rotor blade (4) onto the motor shaft (7) and fasten it using the
appropriate mounting screw (3). Make sure that the individual components are
properly mounted on the motor shaft (7) to avoid vibrations!
7. Mount the protection cage ring (2) to the front protective cage (1) and connect
it to the rear protection cage (6). The protective cage lock (19) is located at the
bottom of the two cages.
8. Fasten the lock (19) with the protective cage locking screw (18).