Uniteck UNISOLAR 10.24S Mode D'emploi page 24

Regulateur de charge solaire pwm
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
Error message
Red charge light.
Consumers are cut
(12/24V light off).
Red
Battery lights:
- AGM,
- Gel
- Liquid
Blinking
simultaneously
24/40
Causes
Battery deeply discharged.
Thermal protection: internal
solar charge controller
temperature exceeds 85°C.
Solar charge controller in a
protection state. Charge and
consumers are cut
www.uniteck.fr
Solution
Usual behaviour: Light turns
green as soon as the battery
is charged.
Wait the end of the cooling-
off period (<75°C)
Control the source of the
overheating (mounting
location, other heat sources).
Provide an adequate
ventilation to the solar
charge controller
As soon as the solar charge
controller gets back to its
normal functionning
temperature, it will restart
automatically.