ANOMALIES, CAUSES, REMEDIES

Error message

No light switch on
Panel light turned off
while sun is present
Blinking panel light
(green)
Green +
Flash
Orange charge light
Orange
Causes
The solar charge controller
needs the battery voltage to
be higher than 6V to be able
to start when connecting the
battery
Battery polarity reversal
Battery connection problem
(cables, terminals...)
Defective battery
Solar panel disconnected, not
properly connected, or short
circuit
Normal functionning:
The panel voltage is lower
than the battery voltage or
too low sunshine.
One or several cells of your
panel are hidden.
Battery overvoltage
Battery discharged
www.uniteck.fr
Solution
Check the battery voltage,
recharge it if necessary.
Check connections
Replace your battery,
following the disconnection
and connection order (see
installation and connection)
Check connections (polarity
and connection)
The panel gets its charge back
as soon as the panel voltage is
higher
than
the
voltage.
Check if your panel is clean
and make sure none of the
cells are hidden.
Disconnect the solar panel,
then make sure the battery is
not in a overvoltage state or
that the voltage of your
battery coupling does not
exceed the voltage accepted
by the solar charge controller
(12V/24V)
Usual charge, light turns
green as soon as the battery
is charged.
23/40
EN
battery