- Fasten the external sensor support to the wheel balancer body using the three screws
supplied with the machine (A, Fig.5a);
- Insert the external sensor pin (B, Fig.5a) in the sensor mounting bush (C, Fig.5a);
- Screw the screw (D, Fig.5a) bringing it closer to the sensor pin without touching it;
- Make sure that the external sensor rotates freely;
- Connect one of the connectors on the sensor cable to the socket on the body of the
sensor itself (H, Fig. 5b);
- Tape the cable to the sensor support (F, Fig. 5a) so that it is never tensioned;
- Connect the other sensor cable connector to the machine's rear panel (G, Fig. 5a);
- Fit the flange holder slides (5, Fig.8), fitting the balancing accessories in the specific
mounts;
- Turn on the machine and make sure it operates correctly.
IMPORTANT: after installing the external sensor, calibrate the sensor as described in
the paragraph "Width sensor calibration".
Fixing machine to ground
- Remove the two brackets by
unscrewing the two M8x60 hex
head screws fixing the machine to
the pallet;
- These brackets are used to fix the
machine to the floor;
- Position the machine on the ground
in the selected position and make
sure that the surrounding spaces
correspond to the minimum values
indicated in Fig. 6/6a;
- Trace the position for drilling on
the floor;
- Drill in the traced position and then
User manual S 65