Fitting procedure
■ Adjusting the horizontal parallel shift adjustment knob ⓑ
(Markings)
■ Adjusting the tilt adjustment knob ⓒ
(Markings)
■ Adjusting the left vertical adjustment knob ⓓ and right vertical adjustment knob ⓔ
(Markings)
■ Alignment procedure
① Adjust the adjustment range gauges of the
unit that will serve as the base position to
their center positions. (They are set at the
center position upon shipment.)
② Based on the base position, adjust the
position using adjustment knobs (1) to (4), in
that order.
③ Check that the magnets of the surface
alignment magnets Ⓖ enter the holder of the
adjacent surface alignment magnets Ⓖ and that
the main unit's screen is lined up.
* For the order in which the units should be installed
when mounting multiple units, see page 29.
Note
• The magnets are strong and may stick when
adjusting, interfering with the adjustment.
If so, pull out the main unit and push it back
in place repeatedly as you adjust.
32
Turn towards the back (
Turn towards the front (
ⓑ-Gauge
ⓓ -Gauge
): Unit moves right in parallel, remaining level.
): Unit moves left in parallel, remaining level.
Turn clockwise (
Unit tilts towards the back.
Turn counterclockwise (
Unit tilts towards the front.
ⓒ -Gauge
Turn clockwise (UP):
Unit moves upwards.
Turn counterclockwise (DOWN):
Unit moves downwards.
Ⓖ Surface alignment magnets
Holder
(no magnets)
):
):
ⓔ-Gauge
Magnets