Important Safety Information; Installation Notes; General Warnings - Jensen 142NG Manuel Du Propriétaire

Masquer les pouces Voir aussi pour 142NG:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

IMPORTANT SAFETY INFORMATION

Installation notes

Minimum Clearance from unit to combustible materials:
48" (121.9 cm) from all sides and back. Do not place this fire table under any overhead structure or
vegetation. Do not place on or above combustible surfaces.
If stubbing out a natural gas hook-up below the table, the installer must make sure that provision is
made for the hose to not contact any side or base panel of the burner area when the fire table is in its
normal operating position.
Save these instructions for future reference. If you are assembling this unit for someone else, give this
manual to them to read and save for future reference.
If the information in this manual is not followed exactly, a fire or explosion may result causing property
damage, personal injury, or death.
Installation and service must be performed by a qualified service agency or gas supplier. Real Flame
recommends using professionals who are certified in the U.S. by the National Fireplace Institute® (NFI)
as NFI Gas Specialists.
Installation of this fire table must conform with local codes or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1 • NFPA 54; National Fuel Gas Code; Natural Gas and Propane
Installation Code,
CSA B149.1; or Propane Storage and Handling Code, CSA B149.2, as applicable.
The normal NG inlet pressure for this appliance is 7.0" W.C. (1.74 kPa), maximum inlet pressure is 10.5"
W.C. (2.61 kPa), minimum inlet pressure is 3.5" W.C. (0.87 kPa).
Do not remove the feet from the fire table.
Do not place the fire table on anything that blocks or seals the gap between the table and the ground.
Do not permanently secure the fire table in any way or to any surfaces.
Do not bury the hose. You must be able to visually inspect the hose for damage before each use.
Do not coil or hide the hose under the fire table. The hose could be damaged if it touches hot
surfaces.

General Warnings

Children and adults should be alerted to the hazards of high surface temperatures and should stay
away to avoid burns or clothing ignition.
Young children should be carefully supervised when in the area of the fire table.
Clothing or other flammable materials should not be hung from the fire table or placed on or near
the appliance.
Any guard or other protective device removed for servicing the fire table must be replaced prior to
operating the appliance.
Installation and repair should be done by a qualified service person. The fire table should be
inspected before use and at least annually by a qualified service person. More frequent cleaning
may be required as necessary. It is imperative that the control compartment, burners, and
circulating air passageways of the appliance are kept clean.
Do not store or use gasoline or other flammable vapors or liquids within 25 feet ( 7.62 m) of this or
any other appliance.
Do not store combustible materials in the fire table enclosure. This includes LP tanks.
Be sure to protect the hose and its components from any hot surfaces. It is dangerous to allow the
hose to come into contact with any hot surface.
Keep all parts of the fire table clean including the burner and hose assembly. For more information on
cleaning your fire table please refer to the Care and Cleaning section of this manual.
3

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

142ng-cbn

Table des Matières