Maintenance; Cartridge Replacement - Conglom transform QL014 Manuel De L'utilisateur

Armoire de rangement avec evier en acier inoxydable et robinet
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Maintenance

CARTRIDGE REPLACEMENT

- Turn off the water supply to the faucet .
- Unscrew the handle lever (19). Loosen the set screw (20) with the hex key and remove the handle
body (21).
- Gently unscrew the decorative cap (22) and retaining nut (23).
- Pull the cartridge (24) out of the faucet body (25) and replace it with a new ceramic cartridge.
Ensure new cartridge is seated properly with the locating pins in appropriate place .
- Secure the cartridge in place using the retaining nut (23).
- Gently tighten the retaining nut (23) using a wrench. Do not overtighten.
- Reinstall the decorative cap (22). Slide the handle body (21) back onto the cartridge and make
sure it rotates freely. Secure the handle body (21) in place using the set screw (20) and reinstall
the handle lever (19).
- Turn the water supply to the faucet back on .
- Operate the faucet to make sure everything works correctly and check for leaks .
Please contact cs@conglomkb .com or 1-877-333-0098 for further assistance .
Retaining Nut (23)
Cartridge (24)
Faucet
body (25)
Decorative
Cap (22)
11
Handle
Lever (19)
O-Ring (26)
Set Screw (20)
Handle
Body (21)
CONGLOMKB .COM