To remove the vermiculite components, first remove the side panels and then the rear panel
(Fig.
20).
WARNING: handle the vermiculite panels very carefully as they do not withstand impacts.
Cleaning the ceramic glass
Always clean the glass when the appliance is off and has cooled down completely. Use a damp cloth or a detergent specifically formulated for ceramic
glass. Do not use abrasive sponges. Do not clean the glass if still warm; changes in temperature can lead to breakage.
Cleaning the flue
The flue must be cleaned at least once a year, at the beginning of winter, and whenever it becomes necessary.
It is important to check for any obstructions in the flue before switching the appliance on following long periods of inactivity.
If the flue is not cleaned, the operation of the appliance and its components may be compromised.
The cleaning frequency of the appliance and flue depends on the quality of the pellets used.
USE TOP QUALITY PELLETS TO OBTAIN THE BEST RESULTS.
Maintenance
Timely and systematic maintenance is essential for guaranteeing correct operation, optimal heat performance and durability of the device. Therefore,
qualified staff should check the appliance at least once a year at the beginning of the season.
You must periodically check the seals because the latter guarantee the air- and water-tightness of the appliance and its good functioning; if they are
worn or damaged you need to be replace them immediately by contacting a Klover Authorised technical assistance centre.
For proper operation, the appliance must undergo routine maintenance performed by a Klover Authorised technical assistance centre at
least once a year.
ELECTRICAL DIAGRAMS AND PARAMETER TABLES
Wiring diagrams and device parameters are visible by scanning the following QR Code with your smartphone.
Electrical Diagrams
Parameter Tables
https://docs.klover.it/it/guide/help/cs-sche-l023-8_l-1
https://docs.klover.it/it/guide/help/cs-w110-par-1