PROBLEM
The burner will not light
using the ignitor procedure.
The burner will not light
with a match
Low heat
Excessive flare-ups
LP Gas Grill

TROUBLESHOOTING

POSSIBLE CAUSES
1. The igniter electrode may be
covered with grease or residue.
2. The igniter electrode may have a
loose or disconnected wire.
3. No spark is being generated
1. No gas flow or an obstructed gas flow
1. The LP-Gas regulator is equipped with an excess
flow device that allows sufficient gas to the burners
under normal cumstances. Rapid changes in
pressure can trigger this device and prevent all but
minimal flow of gas to the burner, causing a low
flame and low heat output. This is typically caused
by the LP-Gas cyliner valve being turned open
when one or more burner valves (control knobs)
is in the open position causing a surge of pressure
that activates the excess flow device.
1. Grease and/or residue build-up on heat tents
or in firebox.
2. Excessive dripping of fat or marinade from food.
POSSIBLE SOLUTIONS
1. Clean the ignitor electrode.
2. Check the connection
and reconnect any loose or
disconnected wires.
1. Check the fuel level, and if necessary,
refill cylinder.
2. Clean the burner inlet (venturi) and burner
as described in the Manual.
Follow these steps:
1. Close the LP-Gas cylinder valve on the
top of the cylinder.
2. Make sure the burner valves are in
the 'OFF" position.
3. Slowly open the LP-Gas cylinder valve
and wait for 10 seconds.
4. Follow the lighting instructions.
1. Clean the grill components.
2. Trim fat from meat and use non-oil
based marinades.