INSTALLATION INSTRUCTIONS
Installation Instruction Top - Stone
Before you start
Rear zone
R
Front zone
F
F
R
Built-in dimensions
67.5 mm
Ø2 mm
Attention: the following instruction applies only to an
installation situation whereby the control knobs are in the
worktop, in combination with a "stone" worktop. See the
"Installation situation table" on page 14.
Choose the right position for the control knobs: in front, to
the left or to the right of the teppan yaki. You can position the
knobs in one of the following ways. This ensures that you can
read the temperature indication on the knob from the user's
position. Before you start, read the "Change zero position knob"
R
paragraph.
F
1. Both the control box and the light rings are fi xed with
screws. You need to create a possibility to fi x the control box
and the light rings. You may do this by glueing a small plank
to the bottom of the granite/natural stone worktop. Add the
thickness of the plank to that of the worktop.
Ø30 mm
R2 mm
Ø30 mm
38 mm
135 mm
P = 270 mm
EN 25
Top-stone
contents
Ø30 mm
Ø2 mm
Ø2 mm
47 mm
Q = 94 mm