13 - OPERATION DEFECTS
This paragraph shows some possible operation defects, along
with their cause and applicable remedy.
In addition to the messages below, the red G2 led located on the
front panel, flashes.
DISPLAYING
OVERLOAD led is on
Too long pre-blinking
Err1
The display shows
Err2
The display shows
Err3
The display shows
Err5
The display shows
Err7
The display shows
Err9
The display shows
DESCRIPTION
It means that there is an overload on
accessory power supply.
When a start command is given, the
flashing light turns on immediately, but the
gate doesn't.
Err1
The writing
appears on display when
you exit from programming
When a start command is given, the door
doesn't open at all
When a start command is given, the door
doesn't open at all
When a start command is given, the door
doesn't open at all
When a Start command is given and the
gate does not open (or does a partial
opening)
When you are trying to change the control
unit setups
SOLUTION
1. Disconnect the terminals L7-L8.
The OVERLOAD led turns off.
2. Remove the cause of the overload.
3. Restore the accessories power supply on terminals
L7-L8 and make sure that the led does not turn on
again.
It means that the setup cycle count down expired and the
control unit shows that service is required (chapter 11.2)
It means that changed data could not be stored.
This kind of defect has no remedy.
Contact the technical support centre V2.
It means that MOSFET test failed.
Contact the technical support centre V2.
It means that the photocell test failed.
1. Be sure that no obstacle interrupted the photocell
beam when the Start command was given.
2. Be sure that photocells, as enabled by their relevant
menus, have been installed actually.
3. Be sure that photocells are powered and working;
when you interrupt their beam, you should hear the
relay tripping.
It means that the test of the safety edges failed.
Check that the menu of the test of safety edges (
have been set correctly.
Check that the safety edges enabled from the menu are
installed.
This indicates an error in the encoders' operation.
Contact the technical support centre V2.
It means that programming was locked by means of the
programming lock key CL1+ (code 161213).
To change the settings it is necessary to insert in the
connector of the ADI interface the same key used to
activate the programming lock, and unlock the device.
- 47 -
Co.tE
)