Screw
Figure 5
1b.
Internal Wire Compartment: If the motor is already installed in the housing, remove the
two screws holding the blower assembly in place. Lift up on the assembly and slide it
out of the tabs on the housing (Figure 6). Remove the wire compartment cover screw
and place the cover in a secure place (Figure 7).
Plug
Screws
Figure 6
NOTE: If the fan motor plug is connected to the fan housing receptacle, unplug so the blower
assembly can be completely removed.
Screw
Figure 7
Standard Models
2a.
Run wiring from an approved wall switch (not included) carrying the appropriate
rating. One neutral (white), one ground (green or bare copper), and one hot (black lead
connected to the switch). Secure the electrical wires to the housing with an approved
electrical connector. Make sure you leave enough wiring in the box to make the
connection to the fan's receptacle.
2b.
From where you have chosen to access the fan's junction box, connect the white wire
from the house to the white wire from the fan's receptacle. Connect the black wire
from the wall switch to the black wire from the fan's receptacle. Connect the ground
wire from the house to the green wire from the fan housing (Figure 8). Use approved
methods for all connections.
Black
Neutral (White)
Green
Figure 8
NOTE: The fan's receptacle wires might need to be pulled outside compartment for connection.
Only pull the five loose wires outside of compartment. Additional wires will be present.
NOTE: Unit must be grounded according to all local and national codes.
6728035 Rev. R 12-18
Wire
Compartment
Cover
Tabs
Wire Compartment
Cover
NOTE: Wire compartment configuration
will be dependent on model.
Black
Switch
(by others)
Neutral (White)
Ground (Green or Bare)
By others
Motion Sensing Models
3a.
Run wiring carrying the appropriate rating. One neutral (white), one ground (green or
bare copper) and one hot (black). Secure the electrical wires to the housing with an
approved electrical connector. Make sure you leave enough wiring in the box to make
the connection to the fan's receptacle.
3b.
From where you have chosen to access the fan's junction box, connect the white wire from
the house to the white wire from the fan's receptacle. Connect the black wire from the house
to the black wire from the fan's receptacle. Connect the ground wire from the house to the
green wire from the fan housing (Figure 9). A manual override switch (not included) can
be used to provide a manual fan Off function. Use approved methods for all connections.
Figure 9
NOTE: The fan's receptacle wires might need to be pulled outside compartment for connection.
Only pull the five loose wires outside of compartment. Additional wires will be present.
NOTE: Unit must be grounded according to all local and national codes.
Humidity Sensing Models
4a.
For proper operation the humidity sensing fan will require a 3 way switch (not included). Run
wiring between the fan and the switch location. Make sure you leave enough wiring in each
box to make the connections. At the switch box connect the black wire from the house to the
common terminal of the switch. Connect the black wire from the fan to one of the switched
terminals on the switch. This position will energize the automatic mode and the fan will
energize upon a rise in humidity. Connect the yellow wire from the fan to the other switched
terminal on the switch. This position will activate the Manual On feature and energize the
fan. Properly connect the ground and neutral (if applicable) mount the switch and the cover.
4b.
From where you have chosen to access the fan's junction box, connect the white wire
from the house to the white wire from the fan. Connect the wire from the automatic
position on the wall switch to the black wire from the fan, connect the wire from the
manual On position on the switch to the yellow wire from the fan. Connect the ground
wire from the house to the green wire from the fan housing (Figure 10). Use approved
methods for all connections.
Black
Yellow
Figure 10
NOTE: The yellow wire may contain a wire crimp nut which will have to be cut off and
the wire stripped.
Motion and Humidity Sensing Models
5a.
Run wiring from an approved wall switch (not included) carrying the appropriate
rating. One neutral (white), one ground (green or bare copper), and one hot (black lead
connected to the switch). Secure the electrical wires to the housing with an approved
electrical connector. Make sure you leave enough wiring in the box to make the
connection to the fan's receptacle.
5b.
From where you have chosen to access the fan's junction box, connect the white wire
from the house to the white wire from the fan's receptacle. Connect the black wire
from the wall switch to the black wire from the fan's receptacle. Connect the ground
wire from the house to the green wire from the fan housing (Figure 11). Use approved
methods for all connections.
www.airkinglimited.com
Black
Black
Neutral (White)
Neutral (White)
Green
Ground (Green or Bare)
Switch
(by others)
Neutral (White)
Neutral (White)
Green
Ground (Green or Bare)
By others
Black
By others
3 of 16