Introduction

Tripp Lite's SRWO8U22 is the perfect multi-option 2-post open frame rack solution for applications where space is limited. 8U, 12U or 22U
rack space options allow configuration flexibility without having to buy separate rack fixtures, all in an out-of-the-way wall-mount form factor.
The SRWO8U22 accommodates all standard 19-inch rackmount equipment compatible with 2-post mounting.

Important Safety Instructions

SAVE THESE INSTRUCTIONS
This Manual contains instructions and warnings that must be followed during the installation and operation of the product described in this
manual. Failure to comply may invalidate the warranty and cause property damage or personal injury.
• Keep the rack in a controlled indoor environment, away from moisture, temperature extremes, flammable liquids and gasses, conductive
contaminants and dust.
• Leave adequate space at the front of the rack for proper ventilation.
• Inspect the shipping container and the rack for shipping damage. Do not use the rack if it is damaged.
• Leave the rack in the shipping container until it has been moved as close to the final installation location as possible.
• Install the rack in a structurally sound area capable of handling the load, the weight of the rack, all equipment that will be installed in the
rack and any other equipment that will be installed nearby.
• Save all packing materials for later use. Repacking and shipping the enclosure without the original packing materials may cause product
damage that may affect the warranty.
• Do not attempt to install the rack unassisted.
• Do not attempt to install equipment without first wall mounting and stabilizing the rack.
• Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the
life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence
of a flammable anesthetic mixture with air, oxygen or nitrous oxide.

Parts List

Top or Bottom Panel
Frames (2)
Right-Side Support Strap
(1)
Short Vertical Mounting
Rails (2)
Left-Side Support Strap
(1)
Long Vertical Mounting
Rails (2)
Mounting Rail Tie Plates
(2)
2
M5 x 10mm
Phillips Head Screws
(16)
M6 x 12 mm
Phillips Head Screws (8)
#12-24 Equipment
Mounting Screws (24)
Zip Ties (8)

Publicité

Table des Matières
loading

Table des Matières