4
tion that is clearly visible to the operator. The PS
830 control unit can be connected directly to the
equipment terminals on the inside of the enclo-
sure to be protected.
By using several LA830 air outlets, it is possible
to achieve a higher volume flow during the purg-
ing phase, which, in turn, leads to a considerably
shorter purging time. Thanks to the built-in spark
and particle barrier in the LA830 air outlet, the
purging air can be released directly into the
explosive atmosphere.
A purging phase may only be carried out with
explosive gas mixtures. Pre-purging is not per-
mitted for applications in explosive dust atmo-
spheres. Here cleaning is necessary to ensure
that there is no dust in the enclosure to be pro-
tected.
The requirements for the enclosure in which the
industrial equipment and components are
installed are met by the U certificate of the empty
enclosure.
–
Compact system (built directly into the
enclosure to be protected or the switch gear
combination)
–
Simple and fast installation of the air outlet
LA830 in the enclosure wall (corresponds
to M40 x 1.5 cable gland)
–
Programming of automatic pre-purging ,
connection for solenoid valve.
–
Two freely programmable output relay con-
tacts (250 VAC / 5 A)
–
Proportional pressure measurement with
high overload protection (no membrane
switch)
–
Visualization of the operating status (inter-
nal enclosure pressure, remaining purging
time and error status via display)
–
Integrated and exchangeable valve fuse in
the PS 830 control unit
–
Selectable languages: German, English,
French, Spanish, Dutch
ZONE 1
ZONE 2
正压系统 PS 830
保护类型«正压外壳pzc的设备保护»使在外壳内
操作工业设备成为可能。 这种类型的基本原理
是通过外壳内的超压来排除爆炸性气体或粉尘
混合。 为了保持内部压力,可以使用仪表空气
或惰性气体作为吹扫气。 所有在壳体内的组件
确定应满足设备保护级别«Gc»或«Dc»的要求。
正压外壳系统通常包括以下设备或部件:
- 要保护的外壳或开关设备组合
- 用于控制过程的PS830控制单元,包括吹扫
- SVD电磁阀;或可选项
- 用于吹扫进料的烧结金属节气门SD840和
- 带有内置火花和颗粒格栅的LA830出风口(
PS830预吹扫系统的特点是灵活的结构,将进
气口、出风口和控制单元在空间上分开。 进气
口或电磁阀和出风口几乎可以安装在正压外壳
或控制设备组合上的任何合适位置。 紧凑的
PS830控制单元可以直接安装在外壳壁上,对
操作者来说是清晰可见的。 PS830控制单元可
以直接连接到外壳内部的设备终端来进行保护
。
通过使用几个LA830空气出口,有可能在吹扫
阶段实现更高的体积流量,这反过来又导致了
相当短的吹扫时间。 由于LA830出风口内置的
火花和粒子格栅,吹扫空气可以直接释放到爆
炸气氛中。
吹扫阶段只能用爆炸性气体混合物进行。 预吹
扫是不适合在爆炸性粉尘环境的。 所以清洁是
必要的,以确保没有灰尘在外壳内。
工业设备和部件外壳的要求带U证书的空外壳。
- 紧凑的系统(直接内置在要保护的外壳或开
- 在围外壳壁简单、快速地安装出风口
- 自动吹扫的程序,电磁阀的连接。
- 两个自由可编程输出继电器触点
- 比例压力测量与高过载保护(无膜开关)
- 操作状态的可视化(内部外壳压力,剩余吹
- 在PS830控制单元的集成和可交换的阀门熔
- 可选择的语言:德语,英语,法语,西班牙
ZONE 21
和报警
也可以安装几个出风口)
关柜组合)
LA830(对应于M40x1.5电缆格兰)
(250VAC/5A)
扫时间和错误状态显示)
断器
语,荷兰语
ZONE 22